FEATURES
& SPECIFICATIONS
Gichner Shelter Systems” Newest
Expandable ISO Shelter is a 20-foor ISO-style shelter
that provides for rapid deployment and expansion. The
Expandable Shelter provides the added floor space needed
for command, Control and Communications systems needs.
When expanded, the One-Side Expandable ISO Shelter (1:2)
provides almost 25 square meters of operational floor
space. When closed, the shelter meets the dimensional
requirements of ISO 668 and ANSI MH5.4 allowing for
transport using all common intermodal transport methods.
The expandable section nests inside the main 20-foot
ISO section during transport. The floor panel of the
expandable section is hinged longitudinally, allowing
the floor section to fold in half when the shelter is
closed for transport. The feature allows for temporary
or permanent mounting of heavy equipment to the floor
of the main ISO section. The flush floor design allows
easy relocation of equipment into the expandable section
for operation. The unique folding floor design also
allows for permanent mounting of equipment on the upper
half of the walls of the expandable section, reducing
the need to move that equipment after deployment. As
an example, electronic equipment may be permanently
mounted to the upper half of the expandable section’s
three walls, allowing for permanent interconnection
of this equipment. Lights, power distribution, and signal
distribution can be permanently installed in both the
main section and expandable section.
Due to the modular design approach, custom configurations
including different length expandable sections can be
manufactured to suit specific system needs. Interior
partitions can be installed to create a separate externally
accessible equipment room, if desired. The unique design
of the shelter permits it to be easily modified to permit
over pressurization for NBC protection for the enclosed
system and personnel.
A Double Side Expandable (1:3) version is also available.
The Single-Side
Expandable weighs 2364 Kg
(5200 pounds)
6727 Kg
(14,800 pounds)
522 Kg/m2 uniform load over the entire floor (107 pounds/ft2)
910 Kg payload (2000 pounds)
366 Kg/m2 uniform load over the entire roof (75 pounds/ft2)
195 Kg/m2 uniform load over the entire roof (40 pounds
/ft2)
Operational: -54 C to 52 C (-65 F to
125 F)
Non-Operational: -62 C to 71 C (-80
F to 160 F)
Center Section: M8 Rivnuts installed
in members withstand 910 Kg (2000pounds) tensile loads.
Potted Inserts installed anywhere withstand 455 Kg (1000
pounds) tensile loads.
Double gaskets at all seams for protection against wind-driven
rain.
Skids: Three full-length replaceable
skids
Three recessed folding steps in sidewall and
one roof handhold
MIL-M-81957(AS)
ISO 1496/1 and ANSI MH5.1.1.1 and 5.4
96 in. high 96 in. wide, 238-1/2 in. long
84-5/16 in. high, 96 in. wide,
238-1/2 in. long
4,200 lbs.
15,800 lbs.
15 years service, 20 years storage
Insulated
to provide a heat transfer coefficient of 0.35 BTU/hr.
ft 2/f
Operation: -40F to +125F plus solar
load to minimum
of +180F
-65F to
+160F
Live
load of 660 lbs. on an area 24 in. by 12 in.; or 75lb.
/ft2uniform snow load
2,000 lb. pullout and 40 inch-lb. torque
|