FEATURES
& SPECIFICATIONS Designed
to meet the shelter performance specification defined
in MIL-S-44408.
Weight:
680 lbs. Payload: 3,300 lbs. Roof Load: Snow
& ice 40 lbs./sq. ft.
660 lbs. over a 2 sq. ft. area. Floor Load: 1,000
lbs. over 3 sq. ft. area
without permanent deformation. Member Loading:
Wall, roof and floor tensile load 1,000 lbs. followed
by 100 inch-pounds torque load 5/16" - 18 UNC inserts.
Temperature Extremes: Operating: -65°F to +125°F
plus solar load. Non-Operating: -80°F to +160°F. Heat Transfer: U-factor 0.40 BTU/hr./sq.ft./°F.
RFI Shielding: With
addition of RFI modification kit, attenuation of 60
dB minimum over 150 KHz to 10 GHz for electric and magnetic
fields and plane waves measure IAW MIL-STD-285. Watertightness:
Tested to 30 inch fording depth and to simulated rainfall. Lifting Eyes: Four
(4) eyes with 3 in. inside clearance. 5,000 lbs. tensile
load per corner in any direction.
Features: *
Roof Access Steps: Two (2) recessed folding
steps in sidewall and one roof handhold *Access
Ladder: Standard ladder with external mounting
bracket